Punkt dostępowy AP1300_P Gigabit AC1200 + adapter Passive PoE 48V
Opis produktu
AP1300 Punkt dostępowy Gigabit AC1200
- Dwuzakresowa prędkość Wi-Fi AC1200
- MT7621DA+MT7613B+MT7603E
- Port Gigabit WAN/LAN
- Tryb 802.3at/af PoE lub Passive PoE lub DC Fat/Fit AP
- W zestawie pasywny adapter PoE 48V
Specyfikacja
- Architektura sieci (switche): GigabitEthernet
- Porty we/wy (sieciówka drobna): 1 x 10/100/1000 Mbit/s PoE
- Pasma (sieci drobne): 5 GHz
- Standardy sieciowe: 802.11a
- Liczba anten (sieci drobne): 4
- Antena (sieci drobne): Wewnętrzna
- Bezpieczeństwo: WPA-PSK WPA2-PSK WPA-PSK/WPA2-PSK WPA2-PSK/WPA3-SAE WPA3-SAE
- Zarządzanie, monitorowanie, konfiguracja: Multiple SSID Enable/Disable Wireless Radio Transmit Power Control QoS(WMM) Seamless Roaming Band Steering MU-MIMO Beamforming Rate Limit Reboot Schedule Wireless Schedule
- Funkcje specjalne: Tryby pracy: Tryb bezprzewodowego punktu dostępowego Tryb routera bezprzewodowego Tryb Bezprzewodowego ekstendera Tryb WISP
- Zasilanie: 802.3af/at PoE 24V lub 48V Passive PoE (+4,5pins; -7,8pins) 12V DC
- Akcesoria w zestawie: Bezprzewodowy punkt dostępowy Zasilacz prądu stałego 12 V Zestaw montażowey Instrukcja instalacji Pasywny adapter PoE 48V
- Kolor (wyliczeniowy): Biały
- Wymiary: 232 x 232 x 57.1 mm
- Wymagania środowiskowe: Temperatura robocza: 0-40°C Temperatura przechowywania: -40-70°C Wilgotność robocza: 10-90% RH bez kondensacji Wilgotność przechowywania: 5-90% RH bez kondensacji
- Pozostałe parametry: CPU: 880MHz Procesor dwurdzeniowy Chipset: MT7621DA+MT7613B+MT7603E Flash: 16MB (128Mbit) DDR: 128MB (1Gbit)
- Uwaga: CE+WEEE
Szczegóły produktu
- Marka Cudy
- Kod produktu 660fc6cb71a267703cbcf5ee
- Dostępność 24 Przedmioty
- EAN13 6971690793272
- MPN AP1300_P
Specyfikacja
-
Pasma Wi-Fi
2.4 GHz
5 GHz
Producent
Producent
Cudy Polska Sp. z o.o.
ul. Nowogrodzka 50/54/515 00-695 Warszawa Polska
E-mail: support@cudy.com
Formularz kontaktowy: https://www.cudy.com/pl-pl/pages/contact
Telefon: 00 86 755 8600 8993
Osoba odpowiedzialna w UE
Cudy Polska Sp. z o.o.
ul. Nowogrodzka 50/54/515 00-695 Warszawa (Śródmieście) Polska
E-mail: support@cudy.com
Formularz kontaktowy: https://www.cudy.com/pl-pl/pages/contact
Telefon: 00 86 755 8600 8993
Bezpieczeństwo
Informacje o bezpieczeństwie
List of safety warnings for WiFi and Access Point Routers based on the requirements of Regulation (EU) 2023/988 on General Product Safety (GPSR) 1. Risk of electric shock: * Make sure that the device is connected to a working socket with grounding. * Do not touch the plug or cable with wet hands. * Avoid using the device in places with high humidity. 2. Risk of overheating: * Provide adequate ventilation while maintaining at least 5 cm of free space around the device. * Do not block ventilation openings. 3. Fire risk: * Use only original power supplies and accessories recommended by the manufacturer. * Do not leave the device on unattended near flammable materials. 4. Hazards at high temperatures: * Do not expose the device to direct sunlight. * Avoid using the router at temperatures above the recommended range (usually 5-35°C). 5. Risk of damage during cleaning: * Before cleaning, disconnect the device from the power supply and use a soft, slightly damp cloth. * Avoid using strong detergents that can damage the surface of the device. 6. Warnings for children: * Keep power cables out of reach of children. * Make sure that children do not play with the device or accessories that can be dangerous. 7. Regularly check the technical condition of the device: * Check the condition of the device regularly for mechanical damage, cracks or other defects. * Do not use the device if it has visible mechanical damage. 8. Use in humid environments * Avoid using your router in the bathroom, in the rain or in other humid environments 9. Interference with other devices * Using a router near medical devices such as pacemakers can cause electromagnetic interference. * Keep a distance of at least 15 cm between your router and medical devices. 10. Regular maintenance * Failure to regularly clean ports and sockets can lead to damage or failure. * Clean ports and sockets regularly using a dry and clean cloth, avoiding moisture input. 11. Risk of loss of water resistance * Do not immerse in water if it is not waterproof. 12. Electromagnetic interference * Smartwatches can interfere with medical devices such as pacemakers. 13. Small parts: * Components of the device, can be swallowed by children. * Keep your device and its accessories out of reach of children. Do not allow children to use the device themselves without supervision. 14. Risk of battery damage * Improper use, such as overheating or using a non-original charger, can lead to battery damage and, in extreme cases, to battery explosion. * Charge your device at room temperature and use only original accessories. Do not expose your smartwatch to high temperatures. 15. Maintenance and cleaning * Impurities such as sweat or dirt can cause discomfort and damage to materials. * Clean your smartwatch and strap regularly with a soft, damp cloth. Avoid using harsh chemicals.
Routery Wi-Fi i Access Pointy
Ostatnio oglądane
Produkty, które ostatnio zwróciły Twoją uwagę.